steam boiler spec - 5 bar fire tube boiler calculation

  • Offshore price : $20000-$100000 Get a quote on the right form
  • Minimum order quantity : 1 set :steam boiler spec - 5 bar fire tube boiler calculation
  • Supply Capacity : 10 units/month :steam boiler spec - 5 bar fire tube boiler calculation
  • Manufacturer/Brand : Fangkuai boiler
  • Port : Anyang
  • payment terms : Letter of Credit, Wire Transfer, VISA

Leave Your Message And Get Price!

I need the quotation of , the fuel is , this capacity is , use for . My Name is , my Email is , my WhatsApp is , Please Send the detail information for me!

Popular products

HOT

θrion Gas Fired Steam Boiler

Capacity:1-20t/h

Rated thermal efficiency: 100-104%

Fixed working pressure: ≤1.6MPa

Applicable fuel:natural gas etc.

consult
HOT

Gas(oil) Fired Integrated Hot Water Boiler

Capacity:0.7-14MW

Rated thermal efficiency:96-98%

Fixed working pressure:≤1.25MPa

Applicable fuel:Natural gas, light oil, etc.

consult
HOT

H6 Gas Fired Hot Water Boiler

Capacity:0.7-2.8Mw

Rated thermal efficiency: 97.2-106%

Fixed working pressure:0.1MPa

Applicable fuel:Natural gas, etc.

consult
HOT

T7 Vacuum Hot Water Boilerr

Capacity:2.8-7.0Mw

Rated thermal efficiency:≥105.5%

Fixed working pressure:-0.02MPa

Applicable fuel:Natural gas, etc.

consult
HOT

V6 Gas Fired Hot Water Boiler

Capacity:99Kw

Rated thermal efficiency:97.2-104.4%

Fixed working pressure:1.0MPa

Applicable fuel:Natural gas, etc.

consult
HOT

Electric Steam Boiler

Capacity:0.5-4.0 t/h

Rated thermal efficiency:98%

Fixed working pressure:≤1.25MPa

Applicable fuel:electric energy

consult

Leave us a message

We will send out plans and quotations within five minutes

Name (optional)

Email

Whatsapp

Choose product type

Message

About us Fangkuai has more than 20 years of experience in R&D and manufacturing of green energy-saving boiler equipment, and is committed to designing and producing boilers that meet customer needs.
Contact us

Global Sales Hotline

telephone:
0086-55929010

Email: [email protected]

Voicemail
  • Steam boiler / fire tube | RITM Industry

    Article: 00013339. Steam boiler / fire tube These types of boilers which are produced in accordance with TSE 337,EN 12953 standards that are used at all industrial systems, CE marked,and tested as per 97/23/EC pressure vessels directive and module B+F.Get Price

  • (PDF) Designing of a Fire Tube Boiler - ResearchGate

    counted for calculation of flat projected surface and refractory covered surface shall not be counted). k. Superheater, drums and boiler tube system maximum design pressure, Vendor to specify, but a minimum of 300 kPa (3 bar) above operating pressure is required. l. Steam drum and boiler tube system maximum design temperatureGet Price

  • Water-tube Package and Industrial Boilers » Babcock & Wilcox

    and more. Backed by more than 5,000 units and 150 years of experience, B&W's water-tube package and industrial boilers have an established reputation for reliability and proven performance. They are engineered to meet unique capacity, space, fuel, emissions, transportation, installation and other requirements. They offer reliable power with low Get Price

  • How to Calculate the Fuel Consumption of the Boiler-ZBG Boiler

    Apr 17, 2019 · The 10 ton gas fired boiler has an output of 10 tons per hour, which is also the capacity of the boiler. To calculate the gas consumption of a natural gas boiler, you need to know the heat resistance of the heating surface of the natural gas boiler, the heat value of the natural gas boiler, and the efficiency of a 10-ton boiler.Get Price

  • "Steinmüller-Tagung" 2013 23. – 24. April 2013

    Lignite fired boiler. Jänschwalde. 535 °C / 175 bar / 815 t/h. Steam Generation – Concepts and Supplies. 5. vertical fire tube boilers Stress calculation • Technical specifications Get Price

  • Section 23 52 39 - FIRE-TUBE BOILERS

    Nov 02, 2017 · hg = enthalpy steam (Btu/lb) hf = enthalpy condensate (Btu/lb) m = steam evaporated (lb/h) Calculate the boiler capacity for example: Boiler capacity = Burner capacity * efficiency. Example: efficiency = 95% & Burner capacity =11,110 kW. boiler capacity =11,110 kW * 0.95. ~=10,500 kW.Get Price

  • (PDF) Steam Boiler - ResearchGate

    2. Steam Boiler. A steam boiler is a closed vessel, generally made of steel, in which water is heated by. some source of heat produced by combustion of …Get Price

  • Design of Boilers (With Diagram) | Thermodynamics

    Design of Cochran Boiler: It is a Fire tube, Stationary, Multi-tubular, Internally fired, vertical boiler. Cochran boiler is made in many sizes capable of producing steam upto 3 T/hour and working pressures upto 17 bar. This boiler gives Thermal efficiency (ƞ th) of 70% with coal firing and about 75% with oil firing.Get Price

  • Recommended ABMA & ASME Boiler Water Limits Boiler …

    salts can precipitate from the boiler water to form sludge and eventually scale, which deposits on the internal surfaces of the boiler. The result: a serious loss of boiler efficiency, and possibly boiler failure. Scale is a buildup of solid material formed on internal boiler surfacesGet Price

  • Project Standards and Specifications Steam Boiler Systems

    Steam Boiler Capacity Calculation--ZBGGet Price

  • Boiler Formulas | Johnston Boiler | Top Quality Boiler

    S = 105 – 80. P2. Cut-in Pressure Delta. S = 25. Factor of Evaporation. Water enters the boiler at 225°F. The boiler pressure is 100 psi and the boiler water temperature is …Get Price

  • Boiler Capacity - Engineering ToolBox

    Since the amount of steam delivered varies with temperature and pressure, a common expression of the boiler capacity is the heat transferred over time expressed as British Thermal Units per hour. A boilers capacity is usually expressed as kBtu/hour (1000 Btu/hour) and can be calculated as. W = (hg - hf) m (1) where. W = boiler capacity (Btu/h, kW)Get Price

  • Controlling TDS in the Boiler Water | Spirax Sarco

    Using the figures from Example 3.12.5, if the boiler had been operating at 10 bar g, steaming at 5 000 kg/h and had a feedwater temperature of 80°C (hf = 335 kJ/kg), the change in energy requirement could be calculated as follows: Condition 1, manual TDS control: Blowdown rate = 11.1%. Example 3.12.7. Condition 2, automatic TDS control Get Price

  • An introduction to steam generation and distribution

    (once through boiler) 19 Water-tube boiler 21 MTHS boilers (fire-tube or smoke-tube boilers) 24 Basic overview of boiler controls with reference to EN 12953 25 Water treatment 28 Level controls 29 Feedwater pump arrangements 30 Burners 33 Basic steam distribution 37 How steam moves (simple explanation) 41 On the motion of steamGet Price

  • Technique EDVHGRQ,%5FRGHV

    an external furnace and shell-type boiler in a sequence. Fire tube boilers of smaller size are vertical and those of larger size are horizontal. The minimum capacity of a water tube boiler is usually around 5 tph. Combo boilers are generally used for solid fuel firing in lower ranges of up to 30 tph for lower pressures <25 atm . 2.Get Price

  • Proper sizing of Boiler Feedwater System - P C McKenzie

    BHP X 34.5 ÷ 8.337 lbs ÷ 60 min. X 10 = minimum useable capacity in gallons. For example, if you have a 500 HP boiler the calculation will be as follows –. 500 x 34.5 ÷ 8.337 ÷ 60 X 10 = 345 gallons. Now, it stands to reason that you can't operate your tank totally flooded so you have to allow for some extra room.Get Price

  • Part II. Energy Efficiency by Sectors Energy Efficiency in

    Water Tube Boilers Used for high pressure high capacity steam boiler Available in sizes that are far greater than the fire tube design. Up to several million pounds per hour of steam. Able to handle higher pressures up to 5,000psig Recover faster than their firetube cousin Have the ability to reach very high temperaturesGet Price

  • Home - Velocity Boiler Works

    The Phantom Combi is an energy efficient boiler with 95% AFUE that can not only heat your home but also provide domestic hot water all from one boiler. Available in 3 sizes with heating and domestic hot water inputs up to 180 MBH and a 10:1 turndown, the Phantom Combi is one of our most versatile condensing boilers. Learn More.Get Price

  • Boiler Capacity - Engineering ToolBox

    Since the amount of steam delivered varies with temperature and pressure, a common expression of the boiler capacity is the heat transferred over time expressed as British Thermal Units per hour. A boilers capacity is usually expressed as kBtu/hour (1000 Btu/hour) and can be calculated as. W = (hg - hf) m (1) where. W = boiler capacity (Btu/h, kW)Get Price

  • CHAPTER TWO: Boiler Operation Maintenance & Safety Study …

    1. Water tube. 2. Fire tube. In water tube boilers, water circulates through the tubes and hot products of combustion flow over these tubes. In fire tube boiler the hot products of combustion pass through the tubes, which are surrounded, by water. Fire tube boilers have low initial cost, and are more compacts. ButGet Price

  • Steam Boilers 30-50HP - Parker Boiler

    Low NOx Model. CAD Drawings. Literature. 30 to 50HP Steam Boilers. The Parker Boiler water tube design offers an extremely efficient, reliable steam boiler built for the long term and ease of maintenance. The Parker Boiler design offers many advantages. Compare ours to the competition. Parker Boiler Certifications.Get Price

  • CHAPTER TWO: Boiler Operation Maintenance & Safety Study …

    1. Water tube. 2. Fire tube. In water tube boilers, water circulates through the tubes and hot products of combustion flow over these tubes. In fire tube boiler the hot products of combustion pass through the tubes, which are surrounded, by water. Fire tube boilers have low initial cost, and are more compacts. ButGet Price

  • SELECTION OF THE OPTIMUM NDT METHODS FOR …

    In contrast to standard practice in Greece, the boiler is installed on the roof of a multistory industrial building in downtown Piraeus, so removal of the boiler intact is very expensive. The existing old steam boiler at G. Keranis Tobacco S.A., Piraeus is a special type of water tube boiler with vertical tubes (Rheinstahl – Henschel IK 5-12 IS).Get Price

  • Boiler Water Conductivity Measurement Fundamentals

    Feb 24, 2016 · A boiler water sample has an un-neutralized conductivity of 5 000 µS / cm at 25°C. What is the conductivity of the boiler water at 10 bar g?At 10 bar g, saturation temperature = 184 °C (from steam tables) σT = 5,000 [1+0.02(184-25)]Get Price

  • Knight Fire Tube Boiler | Residential Boilers | KNIGHT

    KNIGHT™ Fire Tube Boiler. Consistency in features and benefits across the KNIGHT Fire Tube Boiler family makes it easier to install and service no matter what model you choose. 6 Models from 55,000 to 285,000 Btu/hr. 95% AFUE. Up to 10:1 Turndown Ratio.Get Price

  • Steam boilers from Bosch - highly efficient and reliable

    Universal steam boiler CSB. Available in six output sizes, from 300 to 5,200 kg/h for pressures ranging between 0.5 and 16 bar. High efficiency rating of up to 95.3% with integrated economiser and helical heat exchanger tubes. Versatile design for use with different fuel types and as a multi-fuel firing unit (oil, gas, biogas, hydrogen)Get Price

  • MODEL BOILERS - Plans for Everything

    boiler top. The steam-pipe is a circle of 5/16-inch copper tube, having one end closed, and a number of small holes bored in the upper side to collect the steam from many points at once. The other end is carried through the side of the boiler. Page 5Get Price

  • Rite Boilers - "Performance You Can Trust - Efficiency You

    Our boilers are used in industrial paint booths, galvanizers, and many other finishing applications. If you are replacing an old boiler or designing a new building we have the equipment for all of your non-condensing applications. We offer the high efficiency hot water boilers and easy to maintain low pressure steam boilers.Get Price

  • Hot Water Solutions Since 1939 | Lochinvar | Lochinvar

    Arena and convention center look to Lochinvar for accurate, dependable pool heating for world-class swimming trials. View Article. Lochinvar Unveils CREST® Condensing Boiler with Hellcat™ Combustion Technology. Cutting-edge technology automatically adjusts combustion to surrounding conditions. View Article.Get Price

  • Fire Tube Boiler - Construction, Types and Its Working

    Fire Tube Boiler Diagram. These boilers include a water level indicator; a pressure gauge, steam stop tap security tap, & a manhole like mountings for providing security as well as simplicity of working. The Fuel burns on the grate of the firebox in the boiler and the resultant hot-flue gases are permitted to flow in the region of cross tubes.Get Price